The F3 key provides a display of the rotor
mimic diagram for the selected unit number. It shows the shorted turns from
the most recent scan.
In this case, unit 2 is running at a high load,
such that the smaller pitch coils (A - E) are "in-zone".At
lower loads
the larger
pitch coils are
"in-zone"
.
|
Colour Coding of Slot Labels:
|
|
Indicates coil has shorted-turns.
|
|
Indicates coil is
"In-zone"
- shorted turn reports are not influenced by magnetic saturation.
|
|
Indicates coil is "Out-of-zone" - shorted turn reports are influenced by
saturation.
|